Specifications |
General Specifications
Tunnel Dimensions – 620 (W) x 420 (H) [mm] ● 24.4” (W) x 16.5” (H)
Max. Object Size – 615 (W) x 410 (H) [mm] ● 24.2” (W) x 16.1” (H)
Conveyor Height 1) – approx. 800 mm (31.5”)
Conveyor Speed at Mains Frequency 50 Hz / 60 Hz – standard: 0.2 / 0.24 [m/s]
Max. Conveyor Load evenly distributed over the whole conveyor 2) – 165 kg (352 lbs)
Resolution (wire detectability) 3) – standard: 39 AWG (0.09 mm Cu) ● typical: 40 AWG (0.08 mm Cu)
Penetration (steel) 3) – standard: 35 mm ● typical: 37 mm
External Dose – <1.0 μSv/h (0.1 mrem)
Film Safety – Guaranteed up to ISO 1600 (33 DIN)
Duty Cycle – 100%, no warm-up procedure required
X-ray Generator
Anode Voltage ● Cooling – 160 kV cp ● hermetically sealed oil bath
Beam Direction – diagonal
Image Generating System
X-ray Converter – L-shaped detector line
Grey Levels Stored – 4096
Image Presentation – B/W, color
Digital Video Memory – 1280 x 1024 / 24 bit
Image Evaluation Functions – VARI-MAT, O2 Plus, OS Plus, HIGH, Organic Enhancement, HI-SPOT, SEN, XPlore, HAD, Opti-Zoom, electronic zoom: stepless enlargement up to 256x and scaling down up to 8x, Optimized Background Contrast Mode
Monitor – Flat Panel LCD Monitor
Additional Features
Features – display of date/time, software counters for: objects, alarms, operating hours, X-ray On hours, user ID-number, luggage marking system (acoustic), display of operating mode, REVIEW-feature of last 8 images, programmable priority keys, standard network inter face, Automatic return mode, USB 3.0 interface, Printer support, IMS (Image Store Sys tem—stores up to 20,000 images), Two Interlock Switches
System Diagnostic Features – Power-on Self-Test (POST), Real-time Background Diagnosis (RBD), Real-time System Feedback (RSF)
Options – X-ACT, HI-TIP, SD Training Software, Extended Image Storage of 500,000 images (HDD), Full Reverse Mode
Accessories – Keyboard holder, Passive In-/Output Roller conveyors, 23” Monitor, Tunnel extensions, Monitor Theft Protection, Mobile Heavy Duty Rollers, Various Test Bags and Cases
Installation Data
X-ray Leakage meets all applicable laws and regulations with respect to X-ray emitting devices
CE-Labelling in compliance with directives 2004/108/EC, 2006/42/EC, 2006/95/EC
Sound Pressure Level < 65 dB(A)
Operating / Storage Temperature 32°F – 104°F / -4°F – 140°F (0° – 40°C / -20°C – +60°C)
Humidity 5% – 95% (non-condensing)
Power Supply 220 – 240 VAC or 110 – 120 VAC + 10% / -15% ● 50 Hz / 60 Hz ± 3 Hz
Power Consumption approx. 0.8 kVA
Protection Class System IP 20 / IP 43
Dimensions ● Weight 4) 2004 (L) x 850 (W) x 1395 (H) [mm] ● approx. 460 kg
78.9” (L) x 33.5” (W) x 54.91” (H) ● approx. 1014 lbs
Mechanical Construction steel construction with steel panels, mounted on roller castors
standard color(s): Silver matt / RAL Bl 11/W1 F12
1) approx. values (adjustable) 2) measured at ambient temperature of 20° and 230V/120V nominal voltage 3) proprietary quality management test piece: steel step wedge, CU wires, belt speed 0.2 m/s4) without control desk, keyboard, monitor(s) etc.
|